08
Apr

Surface Oil Skimmer Case Study

The problem: In a manufacturing environment, oils, coolants and other lubricants are an essential part of operations. However, when these oils get mixed with water, it can create a range of problems. In order to dispose of used water appropriately, or even to reuse the water, it needs to be free of all contaminants. In […]

02
Jan

Case Study: Interfil High Flow Vacume Filtration System 6000LPM

Interfil high flow vacumatic filtration systems for recycling contaminated solutions. The filter is processing 6000 Litres per minute at 2 microns. Have built systems from 100Lpm to 18,000Lpm.

02
Jan

Case Study: IC45AV Centrifuge and Glass Processing Facilities

Interfil IC45AV Self-Cleaning Centrifuge for Continuous operation in Glass Processing Facilities. Cleaner water with automatic discharge of solids. Flow rate 3600 Litres per hour. This installation was setup to remove the fine glass particulate to minimise the down time in cleaning the tanks and give cleaner water at the glass.

30
Nov

Vacume Filter for 90% Dry Sludge

90% Dry Sludge for heavy metals. The Interfil Vacumatic Sludge Dewatering System processing sludge from heavy metals including Iron and Aluminium. The system is processing 50,000Litres per day and generates a astonishing 90% dry cake. The system is our second smallest system RF6/300-720.  We can modify the systems to suit customer specific requirements to meet […]

31
Aug

Case study: Excavation Rain and Groundwater Filtration

This construction site, predominately clay, had 750, 000 Litres of muddy water that was required to be removed before construction could commence. Normally the process would have taken several weeks, waiting for the water to dry, in addition the clay at this site would take a couple of days once the water was gone to […]

10
Feb

Ground Water Remediation Solution – Case Study

The client had an extensive problem with ground water at a site on the East Coast of Australia at risk of contaminating a main river system within 100 yards from the site. The mobile recycling unit was dispatched to site and setup and operational within 3 hours of delivery. The contaminated groundwater consisted of sand […]

10
Feb

Oil water separation by the Interfil Liquid-Liquid Centrifuge

4% Engine Oil and 96% Water is passed through the Interfil IC45 Liquid-Liquid Centrifuge. The results found 100% oil recovery. Flow rate 300Lph. 3000 gravitational forces For information please take a look at our ic45 semi auto clean centrifuge.

18
Oct

How do you filter oil waste from water?

The Vacumatic Vac1450 operating on oily mud’s and water. The system separates the oil solids for landfill disposal and the filtered water is reused at the process. Processing approx 5000Litres per hour. For more information, please refer to our wastewater filtration products here.    

28
Sep

Drilling Fluid Sludge Thickener and Filtration – Wastewater Filtration

Interfil have incorporated a Drilling Fluid Sludge Thickener and Filtration System onto a mobile trailer – taking the drilling and excavation market to a new level in wastewater treatment systems. This system has been designed by Interfil and Fluid Recycling Systems to process drilling fluids and muds down to less than 1% TSS for either […]

09
Sep

Potato Starch – Wastewater Cleaning IC45 Centrifuge

The Potato Manufacturer purchased the Interfil IC-45 Vertical Clean Oil Centrifuge back in February 2014 for cleaning the wastewater from the potato washing and peeling process. The wash water consisted of soil, sand and starch after the peeling/slicing process. The potatoes are loaded into a vertical helical screw conveyor which allows stones to fall to […]

21
Aug

How Does A Vertical Centrifuge Work?

The video below demonstrates how the Interfil IC-45 oil centrifuge has turned the recycling system into a clean water system by using a simple bolt on application: Contact Interfil to discuss how we can build a water discharged centrifuge system to suit your needs.